Used by consumers and professionals for over a decade. The TECO TANK is the result of one of TECO’s most ambitious and comprehensive redesigns of this chiller to-date. New changes include an increase in cooling efficiency and improved usability, functionality and durability.
TECO TK-1000 Chiller integrate an Efficient Cooling Technology
Internationally-recognized high-end compressors and titanium coaxial heat exchangers provide high performance, low energy consumption and low noise levels (most of the noise comes from the fan rather than the compressor).
Digital Thermostat
The setting of functions is intuitive and the temperature detection is accurate, resolution 0.1°C/0.2°F. The setting range is 0°-35°C (32°F -95°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential (0.5°C/1°F). Displayed temperature is in °C or °F and there are security alarms.
Efficient Design
Solid and durable structure designed to guarantee near perfect protection against corrosion. Rotatable in-set water connections, rotatable exhaust conveyor, and smaller form-factor helps facilitate placement of chiller in confined spaces.
Security
International Protection Marking IPX4 (Water splashing against the enclosure from any direction shall have no harmful effect).
Others Features
The top of the chiller is adjustable and allows for the airflow to be positioned in one of four ways, front, back or either side removing the hot air away from the chiller,
The inlet and outlet pipes are recessed on the edge of the unit, enabling the chiller to be placed flush against the wall, ideal for smaller spaces.
The chillers also include a magnetized air filter which can be removed and cleaned with ease.
All of the TANK Chiller lines have an Aluminium structure making them strong and lightweight.
Teco placed the probe in the inflow pipe to make sure that the temperature measured is the actual one from the tank, which hasn’t been cooled yet. This is one of the reasons why we did not notice a drop in temperature on the display shortly after turning the chiller on. If the probe was located in the outflow pipe, it would read a lower temperature shortly after the chiller is on, but it would not be the same as the temperature in the tank. This could lead to frequent on/off cycles of the unit without an actual lowering of the tank temperature.
Aquarium Sizebetween 60 & 200 gallons
Horsepower1/4 HP
Wifi CapableYes
Maximum Pressure8.7 psi
Minimum Flow Rate132 gallons per hour
Maximum Flow Rate211 gallons per hour
In/Out Water Connection5/8" Inside Diameter (ID) (0.63" or 16 mm)
ExchangerTitanium
Supply120V-60Hz
Power Consumption315 Watts
Gas/RefrigerantR290
Minimum Set Point41°F
Maximum Set Point95°F
Weight44.1 lbs (20.0 kg)