Skip to main contentSkip to footer

Tripp Lite PDUMH15ATNET PDU Switched ATS 120V 15A 8 Outlet

Tripp Lite PDUMH15ATNET PDU Switched ATS 120V 15A 8 Outlet

Model: PDUMH15ATNET
Web Code: 10557645
Sold and shipped by

Available online only

Delivery times vary by location. Most Marketplace items leave sellers' locations within 2 business days. Allow additional time for shipping.

Overview

Tripp Lite PDUMH15ATNET PDU Switched ATS 120V 15A 8 Outlet - 8 x NEMA 5-15R - 1.8kVA - 1U Rack-mountable, Zero U Vertical Rackmount
GeneralInterface-Warranty

Warranty

No information available.

Seller Return Policy

Read return policy

Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.

Single phase 15A 120V Auto Transfer Switch / ATS PDU

Built-in Java-free LX Platform interface for 24/7 remote access

Enables redundant A/B power option for single-corded network devices

Separate primary & secondary inputs connect to any two compatible power sources

1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets

Individually switched outlets; Two digit visual current meter

Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases

Product Condition
Brand New
Cable Type
Other

Connectivity

End Type #1
Other
End Type #2
Other
End Type #3
Not Applicable

Features

Maximum Resolution
Standard Definition
Shipping Charges
Free standard shipping on all orders over $500 (before taxes, fees, and promo codes).
Processing Time
Most items ship within 2 business days after an order is placed*. Allow additional time for shipping to your address.
*Please note: If an item you ordered becomes unavailable, you'll be notified and a full refund will be processed within 2 business days.
Shipping Area Restrictions
Shipping is not available in the following areas*:
  • Yukon
  • Northwest Territories
  • Nunavut
*Please note: Shipping area restrictions may vary for large items. If an item can't be shipped to your address, we'll let you know during the checkout process.
Product Category
Return/Exchange Period
Condition